BXYDN - MERCURIC OXIDE CELL
- MSDS: BXYDN
- Manufacturer: DURACELL INC TECHNICAL SALES AND MARKETING GROUP
- Product Name: MERCURIC OXIDE CELL
- National Stock Number: 6135-00-935-2533
Product Identification
Product ID:MERCURIC OXIDE CELL
MSDS Date:01/11/1989
FSC:6135
NIIN:00-935-2533
MSDS Number: BXYDN
Responsible Party
BETHEL, CT 06801
US
Emergency Phone: 203-796-4654/617-449-7600
Info Phone: 800-243-9540/FAX 203-796-4518
Cage: 90303
Contractor
Telephone: 203-796-4000
Cage: 90303
Ingredients
POTASSIUM HYDROXIDE (CERCLA)
CAS: 1310-58-3
RTECS: TT2100000
OSHA PEL C 2 MG/M3
ACGIH TLV: C 2 MG/M3; 9495
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
MERCURIC OXIDE (SARA 302/313) (CERCLA)
CAS: 21908-53-2
RTECS: OW8750000
OSHA PEL 0.1 MG (HG)/M3; Z-2
ACGIH TLV: S,0.025 MG(HG)/M3;95
MERCURY (SARA 313) (CERCLA)
CAS: 7439-97-6
RTECS: OV4550000
OSHA PEL C, 0.1 MG/M3; Z-2
ACGIH TLV: S,0.025 MG/M3; A4;95
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
ZINC (SARA 313) (CERCLA)
CAS: 7440-66-6
RTECS: ZG8600000
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
MANGANESE DIOXIDE
CAS: 1313-13-9
RTECS: OP0350000
OSHA PEL 5 MG MN/M3 CEILING
ACGIH TLV: 5 MG MN/M3
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: SKIN CONTACT WITH ELECTROLYTE
MAY CAUSE BURNS; EYE CONTACT MAY CAUSE SEVERE, PERMANENT INJURY. AT
ELEVATED TEMPERATURES MERCURY VAPORS MAY CAUSE MERCURY
INTOXICATION. CHRONIC: NONE SPECIFIED BY MANUFACTURER.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:SKIN-BURNS, REDNESS, PAIN OR DISCOMFORT.
EYES-PAIN, TEARING, BURNS, BLURRED VISION, REDNESS. INHALED (HG
VAPORS)-WEAKNESS, FATIGUE, ANOREXIA, LOSS OF WEIGHT, DISTURBANCES
OF GASTROINTESTINAL FUNCTION.
Medical Cond Aggravated by Exposure:AN ACUTE EXPOSURE WILL NOT
GENERALLY AGGRAVATE ANY MEDICAL CONDITION.
First Aid
First Aid:SKIN-FLUSH IMMEDIATELY WITH WATER. EYES-FLUSH IMMEDIATELY
WITH LOTS WATER FOR 15 MINUTES. SEE PHYSICIAN AT ONCE.
INHALED-REMOVE TO FRESH AIR.
Fire Fighting
Extinguishing Media:DLA-HMIS: USE MEDIA APPROPRIATE FOR SURROUNDING
FIRE (EG. WATER FOG, CARBON DIOXIDE, DRY CHEMICAL, FOAM).
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
FULL PROTECTIVE GEAR IF CELLS INVOLVED IN FIRE.
Unusual Fire/Explosion Hazard:CELLS MAY RELEASE TOXIC MERCURY VAPOR
WHEN THE INTEGRITY OF THE CAN IS BROKEN.
Accidental Release
Spill Release Procedures:AVOID SKIN & EYE CONTACT. DO NOT INHALE
VAPORS.
Neutralizing Agent:DLA-HMIS: 5% ACETIC ACID SOLUTION.
Handling
Handling and Storage Precautions:USE NEOPRENE, RUBBER OR LATEX-NITRILE
GLOVES WHEN HANDLING LEAKERS. STORE AT ROOM TEMPERATURE.
Other Precautions:AVOID MECHANICAL OR ELECTRICAL ABUSE. DO NOT ATTEMPT
TO RECHARGE. INSTALL BATTERIES IAW EQUIPMENT INSTRUCTIONS. OBSERVE
CORRECT POLARITY. REPLACE ALL BATTERIES AT SAME TIME. DO NOT MIX
BATTERY SYSTEMS SUCH AS ALKALINE & C/ZN IN SAME EQUIPMT
Exposure Controls
Respiratory Protection:IF ENGINEERING CONTROLS FAIL OR NON-ROUTINE USE
OR AN EMERGENCY OCCURS; WEAR AN MSHA/NIOSH AIR-SUPPLIED RESPIRATOR
OR SCBA, AS REQUIRED. USE IN ACCORDANCE WITH 29 CFR 1910.134 AND
MANUFACTURER'S RECOM MENDATIONS.
Ventilation:SUBSEQUENT TO A FIRE PROVIDE AS MUCH VENTILATION AS
POSSIBLE.
Protective Gloves:LEAKERS-NEOPRENE, RUBBER, LATEX-NITRILE.
Eye Protection:LEAKERS-SAFETY GLASSES.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER. DLA-HMIS:
EYE WASH STATION & SAFETY SHOWER.
Work Hygienic Practices:WASH HANDS AFTER HANDLING AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health
PRODUCT PURCHAED UNDER CONTRACT NUMBER DAAB07-89-D-C003.
Chemical Properties
HCC:N1
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BATTERY, DRY. 0.662 INCHES DIAMETER X 1.752 INCHES
LONG; 5.4 VOLTS. CYLINDRICAL
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:DO NOT HEAT, DISASSEMBLE, CRUSH, PUNCTURE
OR RECHARGE.
Hazardous Decomposition Products:WHEN HEATED, CELLS MAY EMIT HAZARDOUS
MERCURY VAPORS AND CAUSTIC POTASSIUM HYDROXIDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:DO NOT INCINERATE. DISPOSE IF IAW LOCAL, STATE
AND FEDERAL REGULATIONS. DO NOT DISPOSE OF IN FIRE. LARGE
QUANTITIES OF CELLS SHOULD BE TREATED AS HAZARDOUS WASTE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.